江苏十一选五开奖历史开奖结果|江苏十一选五三十五期开的什么号
美国电能设备有限公司
 
 
请输入关键字:
 
     
   当前位置:首页 > 产品展厅 > 详细介绍
   
 
产品名称:  APK无功补偿智能控制器
发布日期:  2008-10-12
查看数次:  15249
  产 品 详 细 介 绍
APK®无功功率智能补偿控制器
APK® inactive power intelligent compensation controller
一、产品简介
Ⅰ    Description of product
1.全数字化设计,交流采样,人机界面采用大规模LCD中文液晶显示器。
1.    Complete digital design, AC sampling, human-machine interface applies the large scale LCD in chinese.
2.    人性化的设计,模块化组装,外观流线设计。
2.    Humanism design, module assembly, streamline design of appearance.
3.    可实时显示L1,L2,L3相的功率因数、电压、电流、有功功率、无功功率、电压总谐波畸变率、电流总谐波畸变率、频率的平均值及电容投切状态等信息。
3.    Display on real time power factor, voltage, current, active power, inactive power, total harmonic distortion rate of voltage, total harmonic distortion rate of current, average value of frequency and switching status of the capacitor in three phases of L1,L2,L3
4.    设置参数中文提示,数字输入。
4.    Set up information of parameter in Chinese, digital input.
5.    电容器控?#21697;?#26696;支持三相补偿,分相补偿,综合补偿方案,可通过菜单操作进行设置控?#21697;?#26696;。
5.   Capacitor control scheme support three phase compensation, phase spliting compensation, comprehensive compensation scheme, the control scheme can be set up through menu operation.
6.    电容器投切控制程序支?#20540;?#23481;、编码(1:2    1:2:3   1:2:4:8 。。。)及模糊控制投切方式。
6.    Switching program of capacitor support isovolumic, coding (1:2    1:2:3   1:2:4:8 ) and fuzzy control switching way.
7.    具有手动补偿、自动补偿两种工作方式。
7.    Manual compensation and automatic compensation two operation modes are available.
8.    取样物理量为无功功率,具有谐波测量及保护功能。
8.    Sampling physical parameter is inactive power which has functions of harmonic measurement and protection.
9.    控制器具有RS-485,MODBUS标准现场总线通讯接口,方便接入只能开关柜?#20302;场?/DIV>
9.    Controller has RS-485,MODBUS standard field bus-bar communication interface and facilitate connect to switch board system.
二、技术参数
Ⅱ. Technical parameter
测量电压:100V~290V
Metering voltage: 100V~290V
测量电流:0~6000A
Metering current: 0~6000A
测?#25239;?#29575;因数:滞后0.200~超前0.200
Metering power factor: lag 0.200~ exceed 0.200
工作电源:220V±%
Working power supply: 220V±%
灵敏度:50mA(二次)
Sensitivity: 50mA (two times)
显示有功功率:0~6553KW
Displayed active power: 0~6553KW
显示无功功率:0~6553Kvar
Displayed inactive power: 0~6553Kvar
显示电压总谐波畸变率:0.0~100.0%
Displayed total harmonic distortion rate of voltage: 0.0~100.0%
显示电流总谐波畸变率:0.0~100.0%
Displayed total harmonic distortion rate of current: 0.0~100.0%
 
接线图
Cable connection figure

型号示例:APKJKWF:APK®无功功率智能补偿控制器
Sample of type:APK® inactive power intelligent compensation controller
 
常见问题及解决方法:
Common problem and solution:
由于一些可能出现的接线、设置、?#24067;?#25925;障等,会造成整个电容补偿?#20302;?#19981;能正常工作,现将较多出现的故障及检查排除方法介绍如下:
The entire capacitance compensation system can not operate normally because of some possible fault in cable connection, configuration and hardware. See below fault which happed frequently and its exclusion method:
1.       控制器测量电流显示值错误或为000
检查参数设置菜单“电流变?#21462;?#35774;置项,其设置的?#24403;?#39035;与主进线电流互感器的比值相同,如主进线取样电流互感器变比为800/5,控制器“电流变?#21462;?#35774;置值应为160;当电流显示0000A?#20445;?#34920;示没有电流信号,应检查电流互感器与控制器电流连接端子线路有开路或没有负载两?#26234;?#20917;。
1.    Value of the controller meter current displays wrongly or is 000
Check “current conversion ratio” setting option in parameter setting menu, setting value should be same as the conversion ration of the main incoming current transformer. In case the conversion ration of the main incoming sampling current transformer is 800/5, the “current conversion ratio” setting value of the controller should be 160; When it displays that the value of the current 0000A, it means no current signal, please check open circuit or no load conditions of the current transformer and the current connection terminal circuit of the controller.
2.       控制器报警指示灯亮
当电压、谐波测量显示值超出设定的上、下限保护值的范围?#20445;?#25511;制器报警指示灯亮。控制器将按“5s”间隔时间?#35856;?#24050;投入电容器,应适当调整上、下限保护值。
2.    Alarm indication lamp of controller is lighted.
When display value of voltage is out of the scope of upper and lower limit protection value, alarm indication lamp of controller is lighted. Controller is switched off at “5s” time interval and the capacitor is switched on, the upper and lower limitation protection value should be suitably adjusted.
3.       功率因数显示错误
应检查控制器的测量电流和测量电压的对应关系,测量电流与测量电压应为同相。
3.    Display of power factor is wrong.
Check the corresponding relationship between metering current and metering voltage of controller, the metering current and the metering voltage should be in-phase.
4.       补偿效果不好
应检查控制器参数设置项,与补偿精度相关参数有“目标cosΦ?#20445;?#38376;限”、“电容容值”三个参数,?#21830;?#39640;“目标cosΦ”值,减小“门限”设定值,推荐设置为目标cosΦ:1.00,门限1.0,每组电容容值设定与实际电容容值相同即可。由于一些设计电容容量分配级差较大,推荐使用电容编码方式,调整电容器容量,将会达到理想补偿效果。
4.    Bad compensation effect
Check parameter setting option of controller. The parameters which are related to the compensation precision are target cosΦ, threshold and capacitance three parameters.  The target cosΦ can be improved and the setting value of threshold is reduced, it is recommended that target  cosΦ is 1.00 and threshold is 1.0, the capacitance of each group of capacitors should be same as that of the actual capacitor. Because the capacity distribution stage difference of some design capacitors are much, it is recommended to apply capacitor coding method and the capacity of the capacitor is adjusted, it would reach the ideal compensation effect.
5.       不便判断问题出在外接线路?#20445;?#21487;换一台控制器,如出现相同的故障现象,请您务必按以上提示检查外接线路。
5.   In case it is difficult to judge that problem occurs on the outer connection line, please replace with another controller. If same fault phenomenon appears, you should check the outer connection line following above mentioned procedure.
 
Bot_Line
  Copyright © 2007-2008 AEPECAPK.COM All rights reserved 沪ICP备17030923号-1  
            

沪公网安备 31010402004178号

江苏十一选五开奖历史开奖结果